CJFVD - NICKEL METAL HYDRIDE BATTERY
- MSDS: CJFVD
- Manufacturer: SANYO ENERGY USA CORP
- Product Name: NICKEL METAL HYDRIDE BATTERY
- National Stock Number: 6140-01-444-9723
Product Identification
Product ID:NICKEL METAL HYDRIDE BATTERY
MSDS Date:05/09/1994
FSC:6140
NIIN:01-444-9723
Status Code:A
MSDS Number: CJFVD
Responsible Party
SAN DIEGO, CA 92173
US
Emergency Phone: 619-681-8820
Info Phone: 619-681-8820
Cage: 00JU0
Contractor
Telephone: 619-661-6620
Cage: 00JU0
Ingredients
NICKEL (POWDER)
CAS: 7440-02-0
RTECS: QR5950000
OSHA PEL 1 MG/M3
ACGIH TLV: 1 MG/M3
NICKEL HYDROXIDE
CAS: 12054-48-7
RTECS: QR7040000
OSHA PEL 1 MG/M3
ACGIH TLV: 1 MG/M3
EPA Report Quantity: 10 LBS
DOT Report Quantity: 10 LBS
COBALT
CAS: 7440-48-4
RTECS: GF8750000
OSHA PEL 0.1 MG/M3
ACGIH TLV: 0.02 MG/M3
MANGANESE
CAS: 7439-96-5
RTECS: OO9275000
OSHA PEL C5 MG/M3
ACGIH TLV: 5 MG/M3
LANTHANUM
CAS: 7439-91-0
CERIUM
CAS: 7440-45-1
NEODYMIUM
CAS: 7440-00-8
RTECS: QO8575000
POTASSIUM HYDROXIDE
CAS: 1310-58-3
RTECS: TT2100000
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
SODIUM HYDROXIDE
CAS: 1310-73-2
RTECS: WB4900000
OSHA PEL 2 MG/M3
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
LITHIUM HYDROXIDE
CAS: 1310-65-2
RTECS: OJ6307070
Hazards
Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:YES
Health Hazards Acute and Chronic:TARGET ORGANS: EYES, SKIN,
RESPIRATORY, AND GASTROINTESTINAL TRACTS. ACUTE - BATTERY IS
HERMETICALLY SEALED. SHOULD THE BATTERIES BE EXPOSED TO EXTREME
HEAT OR PRESSURE CAUSING A BREACH IN THE CASE, D USTS AND FUMES
INHALATION MAY CAUSE IRRITATION OF RESPIRATORY TRACT, EXTREME
RESTLESSNESS, PNEUMONITIS. ELECTROLYTE CAN CAUSE SEVERE EYE AND
SKIN IRRITATION AND CHEMICAL BURNS. EXPOSURE TO NICKEL MAY CAUSE
DERMATITIS IN SOME SENSITIVE INDIVIDUALS. INGESTION MAY CAUSE
LOCALIZED BURNS. CHRONIC - CHRONIC EXPOSURE TO NICKEL MAY RESULT IN
CANCER; DERMAL CONTACT MAY RESULT IN DERMATITIS IN SENSITIVE IN
DIVIDUALS.
Explanation of Carcinogenicity:CONTAINS COBALT AND NICKEL.
Effects of Overexposure:NONE IN NORMAL USE.
Medical Cond Aggravated by Exposure:A KNOWLEDGE OF THE AVAILABLE
TOXICOLOGY INFORMATION AND THE PHYSICAL AND CHEMICAL PROPERTIES OF
THE MATERIAL SUGGESTS THAT OVEREXPOSURE IS UNLIKELY TO AGGRAVATE
EXISTING MEDICAL CONDITIONS.
First Aid
First Aid:GET MEDICAL HELP IF SYMPTOMS PERSIST. INHALED: IF EXPOSED TO
FUMES OR DUSTS, REMOVE TO FRESH AIR AT ONCE AND SEE PHYSICIAN.
EYES: IF THE CONTENTS FROM AN OPENED BATTERY COMES IN CONTACT WITH
THE EYES , IMMEDIATELY FLUSH EYES THOROUGHLY WITHWATER FOR AT LEAST
15 MINUTES. HOLD EYELIDS OPEN. SEE PHYSICIAN. SKIN: IF THE CONTENTS
FROM AN OPENED BATTERY COMES IN CONTACT WITH THE SKIN, WASH WITH
SOAP AND WATER. SWALLOWING: IF BATTERY OR CONTENT OF AN OPENED
BATTERY IS INGESTED, DO NOT INDUCE VOMITING. SEEK IMMEDIATE MEDICAL
ATTENTION. CALL NATIONAL BATTERY INGESTION HOTLINE FOR ADVICE AND
FOLLOWUP (2 02-625-3333), COLLECT, DAY AND NIGHT.
Fire Fighting
Flash Point:NA
Lower Limits:NA
Upper Limits:NA
Extinguishing Media:ANY CLASS OF EXTINGUISHING MEDIUM MAY BE USED ON
THE BATTERIES OR THEIR PACKING MATERIAL.
Fire Fighting Procedures:EXPO TO TEMPS >212F CAN CAUSE VENTIL\NG OF THE
LIQUID ELECTROLYTE. INTERNAL SHORTING COULD ALSO CAUSE VENTING OF
THE ELECTROLYTE. POTENTIAL FOR EXPO TO IRON, NICKEL, COBALT, RARE
EARTH METALS (CERIUM, LANTHANUM NEODYMIUM, & PRASEODYMIUM),
MANGANESE, & ALUMINUM FUMES DURING FIRE: USE SELF-CONTAINED
BREATHING APPARATUS.
Unusual Fire/Explosion Hazard:CELLS MAY RUPTURE AND FORM TOXIC AND/OR
CORROSIVE GASES OR FUMES.
Accidental Release
Spill Release Procedures:SPILL AND LEAKS ARE UNLIKELY BECAUSE CELLS ARE
CONTAINED IN AN HERMETICALLY SEALED CASE. IF THE BATTERY CASE IS
BREACHED, WEAR PROTECTIVE CLOTHING THAT IS IMPERVIOUS TO CAUSTIC
MATERIALS AND ABSORB OR PACK SPILL RESIDUES IN INERT MATERIALS.
PLACE IN AN APPROPRIATE CONTAINER FOR DISPOSAL.
Neutralizing Agent:DILUTE ACID
Handling
Handling and Storage Precautions:STORE IN COOL (-31F TO 95F) PLACE,
BUT PREVENT CONDENSATION ON CELL OR BATTERY TERMINALS. AVOID
BREAKING, CRUSHING OR OTHERWISE DESTROYING THE PHYSICAL INTEGRITY
OF THE CELL OR BATTERY. ELEVATED TEMP ERATURES CAN RESULT IN
SHORTENED BATTERY LIFE. DO NOT OBSTRUCT SAFETY RELEASE VENTS ON
BATTERIES.
Other Precautions:ACCIDENTAL SHORT CIRCUIT WILL BRING HIGH TEMPERATURE
ELEVATION TO THE BATTERY AS WELL AS SHORTEN BATTERY LIFE. THE
BATTERY IS DESIGNED FOR RECHARGING. A LOSS OF VOLTAGE AND CAPACITY
OF BATTERIES DUE T O SELF-DISCHARGE DURING PROLONGED STORAGE IS
UNAVOIDABLE. KEEP OUT OF REACH OF CHILDREN. AVOID MIXIN G WITH
OTHER TYPES.
Exposure Controls
Respiratory Protection:NOT REQUIRED UNDER NORMAL USE.
Ventilation:NOT REQUIRED UNDER NORMAL USE.
Protective Gloves:NOT REQUIRED UNDER NORMAL USE.
Eye Protection:NOT REQUIRED UNDER NORMAL USE.
Other Protective Equipment:EYE BATH, WASHING FACILITY, LAB COAT OR
UNIFORM.
Work Hygienic Practices:GOOD PRACTICE REQUIRES THAT GROSS AMOUNT OF ANY
CHEMICAL BE REMOVED FROM THE SKIN AS SOON AS PRACTICAL.
Supplemental Safety and Health
DO NOT MIX BATTERY WITH OTHER TYPES, CHARGE ABOVE SPECIFIED RATE,
CONNECT IMPROPERLY, OR SHORT CIRCUIT, WHICH MAY RESULT IN
OVERHEATING, EXPLOSION OR LEAKAGE OF CELL CONTENTS.
Chemical Properties
HCC:Z7
Boiling Pt:B.P. Text:NA
Melt/Freeze Pt:M.P/F.P Text:NA
Decomp Temp:Decomp Text:NP
Vapor Pres:NA
Vapor Density:NA
Spec Gravity:NA
Solubility in Water:NA
Appearance and Odor:NO ODOR
Percent Volatiles by Volume:NA
Stability
Stability Indicator/Materials to Avoid:YES
THE BATTERY CELLS ARE ENCASED IN NON-REACTIVE CONTAINER; IF CONT IS
BREACHED, AVOID CONTACT OF INTERNAL BATTERY COMPONENTS WITH ACIDS,
ALDEHYDES, AND CARBAMATE COMPOUNDS.
Stability Condition to Avoid:HEAT, OPEN FLAMES, SPARKS AND MOISTURE.
Hazardous Decomposition Products:OXIDES OF NICKEL, COBALT, MANGANESE,
LANTHANUM, AND CERIUM
Disposal
Waste Disposal Methods:DISPOSE OF WASTE IN ACCORDANCE WITH LOCAL,
STATE, AND FEDERAL LAWS AND REGULATIONS. RECYCLING IS RECOMMENDED.
DO NOT INCINERATE BATTERIES.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.